HP-N32 Table Top Autoclave Machine, Steam Sterilizer
Price, lead time and documents for your market are confirmed in the quotation.
Key takeaways
- Model 1 of 2 in the HP-N32–N33 pair: HP-N32 is a table top autoclave machine for dental and outpatient clinics.
- Shares the HP-N32–N33 body design: a white housing and a large color display beside the door.
- Quote-based supply: send quantity, voltage and destination; the data sheet and market documents come with the quotation.
HOPE INTERNATIONAL lists HP-N32 as the first of the two models in the HP-N32–N33 table top pair: a table top autoclave machine of the steam type. Unlike the gauge-and-knob or keypad panels of other table top pairs, N32–N33 is operated from a large color display beside the door (as pictured). Per-model data sheets let you compare HP-N32 with HP-N33.
Key Features
- Bench-mounted chamber – trays load through a front door at working height.
- As shown in the photo – a white front-loading housing operated from a large color display panel, with a green-trimmed base panel below the door.
- Paired with HP-N33 – same body, separate model number; choose by rated volume.
- No chemical sterilant – steam and pressure do the work; the running inputs are water and heat.
Applications
HP-N32 fits clinics that sterilize instruments between patients during the day: dental and oral surgery rooms, GP and specialist clinics, podiatry, veterinary practices and small labs. If you need an autoclave for dental office use that is run from a large display panel, this pair is the one to check.
How to specify when requesting a quote
- Model – quote HP-N32; add HP-N33 to compare both sizes.
- Daily volume – packs or trays per day, so we can check HP-N32 against the rest of the HP-N32–N33 group.
- Water – ask how HP-N32 is filled; plan for distilled or demineralized water to limit scale.
- Safety features – ask for the protection list of HP-N32: safety valve, interlock, over-temperature, low-water cut-off.
- Quantity – units of HP-N32 and any HP-N models to ship together.
Specifications
| Model | HP-N32 |
|---|---|
| Sterilizer type | Table top |
| Sterilization method | Steam |
| Design group | HP-N32–N33 (2 models) |
Documents
Certificates, declarations of conformity and test reports for the specific model and destination market are provided with the quotation.
An autoclave is both a pressure vessel and an electrical appliance, and import rules differ by country. Tell us where HP-N32 will be installed and we will confirm which pressure-vessel, electrical-safety and registration documents apply; ask for the data sheet and operating manual with your quote.
Frequently asked questions
+What is a Class B autoclave?
Under EN 13060, Class B sterilizers use fractionated (pulse) vacuum and are validated for all load types, including handpieces and wrapped packs; Class N covers unwrapped solid items only, and Class S covers loads the maker specifies. Ask us for the class of HP-N32 before ordering for dental use.
+How do you choose an autoclave for a dental clinic?
The deciding points are load type (hollow handpieces and pouches need Class B), chamber size for your trays, and daily cycle count. HP-N32 is a table top steam sterilizer; we confirm its cycle class on the data sheet; for Class B work, compare our pulse-vacuum table top models HP-P32 to HP-P38 and ask for their test class.
+How long does an autoclave cycle take?
Expect the sterilizing hold plus heat-up, venting, cooling and any drying stage. Higher-temperature programs hold for a shorter time than lower-temperature ones, and wrapped and dense loads take longer than unwrapped instruments. The validated cycle data for HP-N32 is in its manual, which we send with the quotation.
+What is the difference between HP-N32 and HP-N33?
Both models use the HP-N32–N33 body design; the model number is what changes. Ask for both data sheets with your quote – chamber volume, heating power, weight and packed size are listed per model, which is how buyers decide between HP-N33 and HP-N32.